120 V on the sheet
Machines whose input line includes 120 V. Thickest published mild steel first. No thickness number sorts last. The chip still drops a 15 A fail.
| # | Model | 120 V mild steel, published | Duty cycle |
|---|---|---|---|
| 1 | MIG285 | 0.625 in max | MIG: 30% at 285 A on 240 V and 30% at 120 A on 120 V. Stick: 30% at 250 A on 240 V and 30% at 120 A on 120 V. TIG: 30% at 250 A on 240 V and 30% at 120 A on 120 V. |
| 2 | Rebel EMP 235ic | 0.5 in max | At 104°F (40°C): MIG 120 A / 19 V at 40% on 120 V and 235 A / 26 V at 40% on 230 V. Stick 90 A / 23.6 V at 40% on 120 V and 210 A / 28.4 V at 25% on 230 V. TIG 130 A / 15.2 V at 40% on 120 V and 240 A / 19.6 V at 40% on 230 V. |
| 3 | TIG225X | 0.5 in max | TIG: 40% at max output, and 100% at 108 A on 120 V or 155 A on 240 V. Stick: 40% at max output, and 100% at 76 A on 120 V or 139 A on 240 V. |
| 4 | Handler 210i | 0.375 in max | 120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle. |
| 5 | Handler 210MVP | 0.375 in max | 115 V: 90 A at 19 VDC, 20% duty cycle. 230 V: 150 A at 23 VDC, 30% duty cycle. |
| 6 | Multi-Handler 200 | 0.375 in max | At 30% duty cycle: MIG 110 A at 19.5 V on 120 V and 165 A at 22.2 V on 240 V; DC TIG 105 A at 14.2 V on 120 V and 165 A at 16.6 V on 240 V; stick 90 A at 23.6 V on 120 V and 140 A at 25.6 V on 240 V. |
| 7 | Handler 125 | 0.1875 in max | 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. |
| 8 | Handler 140EZ | 0.1875 in max | 90 A at 18.5 VDC, 30% duty cycle. |
| 9 | Millermatic 142 | 0.1875 in max | 100 A at 19 V, 60% duty cycle. 80 A at 18 V, 100% duty cycle. |
| 10 | Millermatic 211 PRO | 0.1875 in max | 120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle. |
| 11 | Multimatic 215 PRO | 0.1875 in max | 120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle, and 215 A at 24.8 VDC, 30% duty cycle. |
| 12 | Syncrowave 212 | 0.1875 in max | Quick specs lead with 130 A at 15.2 V, 60% duty cycle. The table adds, at 60%: 120 V DC TIG 110 A at 14.4 V, and 240 V DC stick 120 A at 24.8 V. It also prints 210 A at 20% and 120 A at 100% on the AC/DC TIG duty column, without tying those two lines to one voltage. |
| 13 | Thunderbolt 210 MV | 0.125 in max | 120 V: 65 A at 60% duty cycle and 50 A at 100% duty cycle. 240 V: 135 A at 60% duty cycle and 105 A at 100% duty cycle. |
| 14 | Dynasty 210 | Not published | 210 A at 18.4 V, 60% duty cycle. |
| 15 | Maxstar 161 STH | Not published | TIG, 120 V: 90 A at 13.6 VDC, 100% duty cycle, and 130 A at 15.2 VDC, 30%. TIG, 240 V: 110 A at 14.4 VDC, 100%, and 160 A at 16.4 VDC, 20%. Stick, 120 V: 60 A at 22.4 VDC, 100%, and 90 A at 23.6 VDC, 30%. Stick, 240 V: 110 A at 24.4 VDC, 100%, and 160 A at 26.4 VDC, 20%. |
| 16 | Multimatic 220 AC/DC | Not published | MIG: 120 V, 105 A at 19.2 V, 60% duty cycle; 240 V, 200 A at 24 V, 20% duty cycle and 170 A at 21.5 V, 40% duty cycle. Stick: 120 V, 90 A at 23.6 V, 40%; 240 V, 200 A at 28.4 V, 15%. TIG: 120 V, 130 A at 15.2 V, 40%; 240 V, 210 A at 18.4 V, 20%. |
| 17 | Power MIG 210 MP | Not published | MIG: 120 V, 100 A / 19.0 V / 40%. 230 V, 200 A / 24 V / 25%. |
| 18 | Power MIG 215 MPi | Not published | 215 A / 24.8 V / 30%. The specifications table prints that one duty-cycle figure beside input power 120/230/1/60. 215 A is above the printed 120 V output range of 20–140 A. |
| 19 | Rebel EMP 215ic | Not published | MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%. |
| 20 | Square Wave TIG 200 | Not published | 120 V TIG: 125 A/25%, 100 A/40%, 85 A/60%. 120 V stick: 75 A/20%, 65 A/60%. 230 V TIG: 200 A/25%, 160 A/40%, 130 A/60%. 230 V stick: 170 A/20%, 100 A/60%. |
| 21 | TIG200 | Not published | Not published |
| 22 | TIG230 | Not published | TIG: 35% at 230 A, 60% at 175 A, 100% at 136 A. Stick: 35% at 200 A, 60% at 152 A, 100% at 118 A. The duty lines are not split by voltage. |
| 23 | TIG325X | Not published | TIG: 40% at 325 A, 60% at 280 A, 100% at 250 A. Stick: 40% at 250 A, 60% at 220 A, 100% at 180 A. The duty lines are not split by voltage. |
| 24 | Unlimited 140 | Not published | GMAW/FCAW 30% at 90 A. SMAW 40% at 75 A. GTAW 20% at 110 A. |
| 25 | Unlimited 200 | Not published | 120 V: GMAW/FCAW 40% at 90 A, SMAW 40% at 70 A, GTAW 40% at 90 A. 240 V: GMAW/FCAW 15% at 200 A, SMAW 15% at 170 A, GTAW 15% at 200 A. |
Use the outlet check when you know the breaker size. Input current at rated output is not the same thing as a recommended breaker.